Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Microbiol Biol Educ ; 25(1): e0015623, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38661408

RESUMO

Students that graduate with degrees in science may pursue a variety of career roles. Many of these roles may require them to read primary scientific literature (PSL) or even write up their own manuscripts for submission. While literature has recognized the importance of integrating PSL into undergraduate curriculum, it is also important for students to recognize the writing process that one may need to take part in if they seek to disseminate their own publications. This article will go through a research assignment that was given to an introductory journal club class for biology majors at a large R1 Hispanic-serving Institution. This assignment was designed to mirror the publication process at many journals including drafting a manuscript, integrating editor recommendations, and drafting a letter to the editor. In the end, students produce a review paper while becoming more familiar with the traditional publication process. In turn, this can prepare them to eventually seek to publish their own manuscripts.

2.
Electrophoresis ; 2024 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-38342679

RESUMO

Cationic surfactant coatings (e.g., CTAB) are commonly used in CE to control EOF and thereby improve separation efficiencies. However, our understanding of surfactant adsorption and desorption dynamics under EOF conditions is limited. Here, we apply automated zeta potential analysis to study the adsorption and desorption kinetics of CTAB in a capillary under different transport conditions: diameter, length, voltage alternation pattern and frequency, and applied pressure. In contrast to other studies, we observe slower kinetics at distinct capillary wall zeta potential ranges. Within these ranges, which we call "stagnant regimes," the EOF mobility significantly counteracts the electrophoretic (EP) mobility of CTA+ and hinders the net transport. By constructing a numerical model to compare with our experiments and recasting our experimental data in terms of the net CTA+ transport volume normalized by surface area, we reveal that the EP mobility of CTA+ and the capillary surface-area-to-volume ratio dictate the zeta potential range and the duration of the stagnant regime and thereby govern the overall reaction kinetics. Our results indicate that further transport-oriented studies can significantly aid in the understanding and design of electrokinetic systems utilizing CTAB and other charged surfactants.

3.
Faraday Discuss ; 246(0): 356-369, 2023 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-37462093

RESUMO

In this study, we present nanofluidic diodes fabricated from straight glass nanochannels and functionalized using bio-inspired polydopamine (PDA) and poly-L-lysine (PLL) coatings. The resulting PDA coatings are shown to be asymmetric due to a combination of transport considerations which can be leveraged to provide a measure of control over the effective channel geometry. By subsequently introducing a layer of amine-bearing PLL chains covalently bound to the PDA, we enhance heterogeneities in the charge and ion distributions within the channel and enable significant current rectification between forward-bias and reverse-bias modes; our PDA-PLL-coated channels yielded a rectification ratio greater than 1000 in a 100 nm channel filled with 0.01× phosphate-buffered saline solution (PBS). We further demonstrated that at higher ionic strength conditions, reducing the solution pH increased the number of protonated amines within the PLL layer, amplifying the charge disparities along the channel and leading to greater rectification. As nanofluidic diodes with bipolar surface charge distributions tend to provide superior performance compared to those with a single wall charge polarity, we imposed a more bipolar charge distribution in our devices by partially coating our PDA-PLL-coated channels with negatively charged polyacrylic acid (PAA). These enhanced bipolar channels exhibited greater current rectification than the PDA-PLL-coated channels, reaching rectification ratios in excess of 100 even in more physiologically-relevant 1× PBS solutions. Our fabrication approach and the results herein provide a promising platform from which the scientific community can build upon in the relentless endeavor for improved sensitivity in biosensors and other analytical devices.

4.
Electrophoresis ; 43(5-6): 741-751, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35019166

RESUMO

We report on the investigation of electropreconcentration phenomena in micro-/nanofluidic devices integrating 100 µm long nanochannels using 2D COMSOL simulations based on the coupled Poisson-Nernst-Planck and Navier-Stokes system of equations. Our numerical model is used to demonstrate the influence of key governing parameters such as electrolyte concentration, surface charge density, and applied axial electric field on ion concentration polarization (ICP) dynamics in our system. Under sufficiently extreme surface-charge-governed transport conditions, ICP propagation is shown to enable various transient and stationary stacking and counter-flow gradient focusing mechanisms of anionic analytes. We resolve these spatiotemporal dynamics of analytes and electrolyte ICP over disparate time and length scales, and confirm previous findings that the greatest enhancement is observed when a system is tuned for analyte focusing at the charge, excluding microchannel, nanochannel electrical double layer (EDL) interface. Moreover, we demonstrate that such tuning can readily be achieved by including additional nanochannels oriented parallel to the electric field between two microchannels, effectively increasing the overall perm-selectivity and leading to enhanced focusing at the EDL interfaces. This approach shows promise in providing added control over the extent of ICP in electrokinetic systems, particularly under circumstances in which relatively weak ICP effects are observed using only a single channel.


Assuntos
Eletricidade , Eletrólitos
5.
Anal Chem ; 93(49): 16512-16519, 2021 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-34851604

RESUMO

Surface coatings are extensively used in capillary electrophoresis to increase separation efficiency and resolution. The stability of these coatings across a wide pH range is desirable to achieve repeatable migration times; therefore, a comprehensive understanding of coating degradation timescales is needed. We present a novel platform for automated zeta potential analysis based upon current monitoring that delivers improved time resolution over the existing methods. Using our platform, we measure the zeta potential continuously during aminosilane coating reactions and infer changes in the surface composition. We found that the change in the zeta potential after coating depended on the monomer type and solvent, while its stability was influenced by the coating solvent and exposure pH. Our versatile platform provides an elegant approach for evaluating the molecular composition, reactivity, and stability of surfaces in real time.

6.
ACS Appl Mater Interfaces ; 11(14): 13777-13786, 2019 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-30880379

RESUMO

Bipolar electrodes (BPEs) are conductors that, when exposed to an electric field, polarize and promote the accumulation of counterionic charge near their poles. The rich physics of electrokinetic behavior near BPEs has not yet been rigorously studied, with our current understanding of such bipolar effects being restricted to steady-state conditions (under constant applied fields). Here, we reveal the dynamic electrokinetic and electrochemical phenomena that occur near nanoconfined BPEs throughout all stages of a reaction. Specifically, we demonstrate, both experimentally and through numerical modeling, that the removal of an electric field produces solution-phase charge imbalances in the vicinity of the BPE poles. These imbalances induce intense and short-lived nonequilibrium electric fields that drive the rapid transport of ions toward specific BPE locations. To determine the origin of these electrokinetic effects, we monitored the movement and fluorescent behavior (enhancement or quenching) of charged fluorophores within well-defined nanofluidic architectures via real-time optical detection. By systematically varying the nature of the fluorophore, the concentration of the electrolyte, the strength of the applied field, and oxide growth on the BPE surface, we dissect the ion transport events that occur in the aftermath of field-induced polarization. The results contained in this work provide new insights into transient bipolar electrokinetics that improve our understanding of current analytical platforms and can drive the development of new micro- and nanoelectrochemical systems.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...